Photovac, MicroFID-II Flame Ionization Detector

  • Image 1
PHO A1201060
11.00 LBS
Shipped from manufacturer in 3-5 business days.
Calculated at checkout

Product Description

MicroFID-II Flame Ionization Detector

Includes Bluetooth communication, 70L hydrogen cylinder, 15-hour rechargeable battery pack, 90-265VAC/50-60Hz universal battery charger, 10 Fluoropore membrane filters, and user manual (download version). Classified Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D hazardous locations.

Note: if used in hazardous locations with PDA or mobile telephone, PDA or mobile telephone must be intrinsically safe.

Innovative Portable Flame Ionization Detection for Volatile Organic Compounds

  • Accurate, reliable flame ionization detection
  • Bluetooth® enabled for wireless communication to handheld computers or mobile phones
  • Unique 70 hour, low pressure hydrogen fuel cylinder
  • Long-life 15 hour battery
  • Intrinsically safe
  • Integrates with GPS positioning system


  • Emergency Response - HazMat
  • Underground Storage Tank Removal
  • Confined Space Pre-entry
  • Arson Accelerant Investigations
  • Soil Gas Monitoring
  • Petroleum Products Tank Entry
  • OSHA Compliance
  • Pollution Control Efficiency

Photovac MicroFID II Specifications

EPA Standards: Meets and exceeds US EPA Method 21 regulations for determination of volatile organic compound leaks.
Detector: Flame ionization
Size: 13"L x 12"W x 3" D (33cm x 30.5cm x 7cm).
Weight: 11.0 pounds (5 kg).
Display: Large 2.8" (7.1 cm) diagonal active area. Backlight manually activated.
Keypad: Four menu keys
Connectivity: Integral wireless Bluetooth technology, installed inside MicroFID II housing.
Monitoring software compatibility: Communicates wirelessly with Photovac's FirstFID software system.
Hand-held device requirements for FirstFID Software: Windows ® Mobile 6 or above, 64MB RAM, Bluetooth 2.0 and 480 x 640 screen resolution. Contact Photovac for details,
Hydrogen operating time: 70 hours
Hydrogen tank pressure: 80psi (2,068 mmHg)
Hydrogen cylinder shipping classification: UN3468. Can be shipped full of hydrogen by way of commercial air.

Re-light after Flame-out: Can be re-lit from monitoring software system.
Battery Capacity: 15 hours
Response time: < 3 seconds
Operating concentration range: 0.1 ppm to 50,000 ppm
Operating temperature range: 32°F (0°C) to 122°F (50°C)
Operating humidity range: 0 to 100% (non-condensing)
Repeatability: +/- 2%
Alarm level: Preset by operator
Alarm: Audible at 85 dB, visual red LED on instrument body
Calibration Standards: Methane, hexane or propane
Intrinsic Safety; Class 1, Division 1, Groups A,B,C & D*
FCC: Class B digital device, pursuant to Subpart B, class B of Part 15 of the FCC rules